Commissioning and maintenance of hydraulic system of profile bending machine

Description

The main shaft drive and 3D guide roll lifting of the profile bending maching (also called angle roller or section bender) are all completed by the hydraulic system. The rated working pressure is 19.5Mpa.

roll of section bending machine
roll of section bending machine

The electromagnetic relief valve is used for no-load starting and the pressure is adjusted for overload unloading. The pressure adjustment range and pressure fluctuations are observed through the pressure gauge.

hydraulic system of profile bending machine

Control form

The section bending machine’s system is in the form of switch control. The condition of the solenoid valve is determined by the condition of the actuator; the hydraulic check valve is used to hold pressure on the edge roller cylinder and the speed control valve is used to adjust Spindle rotation speed and 3D guide roller cylinder lift speed.

According to the requirements of the specific operating conditions of each actuator, a hydraulically controlled one-way valve is provided on the lifting cylinder of the side roller, the lifting and lowering of the idler, and the rotating cylinder circuit to achieve the pressure maintaining function.

In order to observe the different pressure conditions of each branch, a pressure gauge is installed at the overflow valve of each oil pump outlet, so that the pressure condition of the system and each branch can be easily observed.

The oil suction port of the oil pump is also provided with Suction port filter to ensure the cleanliness of the oil entering the system.

The effective volume of the fuel tank of the 45 CM3 Section Bending Machine‘s approximately 160 liters. It is recommended to use about 200 liters of YA-N46 normal hydraulic oil, filtered by a fine oil filter and injected into the tank.
It should be noted that, after the oil has fully entered the pipeline and the fuel tank, the tank should be replenished with oil again, so that the liquid level of the tank reaches the upper limit of the oil level.

Before the Section bending machine leaves the factory, the hydraulic system has been debugged according to the following steps. Users can generally do not need to readjust:

Start the oil pump motor and adjust its direction of rotation by pointing the oil pump up arrow. (Judge that the pump rotation direction should be seen from the end of the pump shaft)

Debugging

When the pump is started or stopped, the system overflow valve should be in the unloaded state; the system pressure should be adjusted to about 5MPA, and the manual solenoid valve should check whether the movement of each cylinder is correct.

The operation of the various actuators was tested several times after power on, and the pressure was increased stepwise by -5Mpa-8Mpa-12Mpa-14MPa—. The test was conducted and the phenomenon of leakage, impact, vibration, etc. was found and checked and eliminated in time.

After the set pressure of the overflow valve is adjusted and determined, the lock nut of the overflow valve shall be tightened to prevent accidents due to machine vibration or artificially arbitrary operation. The idle test run can be performed for a period of time. The gas in the road is fully filtered. After the actuators are stable and reliable, all filter elements are thoroughly cleaned or replaced before the load test can be performed.

Routine maintenance

The system oil temperature should be appropriate. The oil temperature of the tank should not exceed 60℃. Consider the specific environmental conditions;
If the machine works in a hot environment, the hydraulic oil with higher viscosity can be used.

For better conditions and longer service life, minimize the contamination of the oil. Clean or replace the filter element regularly.
Check the degree of deterioration of the oil every six months.
If it exceeds the limit of use, replace it in time and replace it before changing the oil. Exhaust the old oil, clean the fuel tank, filter it into the fuel tank after being filtered by the fine oil filter, and avoid mixture of old and new oil.

Always check the tightness of each pipe joint, whether there is any leakage, and find out that the abnormal situation should be eliminated in time.

The Angle bending machine will be left unused for a long period of time, and the air in the system shall be exhausted after restarting.

Related reading:Daily maintenance of hydraulic system of profile bending machine